Model NumberPower Out Max (kW)Input Voltage (VAC)Output Voltage Range (VDC)Output Current Max (A)Cooling
OPUS C 24 5.5 R 12U F5.5180 - 27521 - 31229ConvectionMore info
Product Specifications
Max # Outputs1
Module Positions5
V1 Out Min (V)21
V1 Out Nom (V)24
V1 Out Max (V)31
Efficiency Rating (%)90
Operating Altitude (m)2000
Operating temperature range-5 to 45°C
SafetyIEC/EN 60950-1
IP RatingIP20
Control & MonitoringVIDI+ or VIDI+ I/O
OPUS C 220 8 R 12U F8.0180 - 275189 - 26533ConvectionMore info
Product Specifications
Max # Outputs1
Module Positions5
V1 Out Min (V)189
V1 Out Nom (V)220
V1 Out Max (V)265
Efficiency Rating (%)91
Operating Altitude (m)2000
Operating temperature range-5 to 45°C
SafetyIEC/EN 60950-1
IP RatingIP20
Control & MonitoringVIDI+ or VIDI+ I/O
OPUS C 48 8 R 12U P8.0180 - 27542 - 58164ConvectionMore info
Product Specifications
Max # Outputs1
Module Positions5
V1 Out Min (V)42
V1 Out Nom (V)48
V1 Out Max (V)58
Efficiency Rating (%)91
Operating Altitude (m)200
Operating temperature range-5 to 45°C
SafetyIEC/EN 60950-1
IP RatingIP20
Control & MonitoringVIDI+ or VIDI+ I/O
OPUS C 48 8 R 12U F8.0180 - 27542 - 58164ConvectionMore info
Product Specifications
Max # Outputs1
Module Positions5
V1 Out Min (V)42
V1 Out Nom (V)48
V1 Out Max (V)58
Efficiency Rating (%)91
Operating Altitude (m)2000
Operating temperature range-5 to 45°C
SafetyIEC/EN 60950-1
IP RatingIP20
Control & MonitoringVIDI+ or VIDI+ I/O
OPUS C 60 8 R 12U F8.0180 - 27551 - 72134ConvectionMore info
Product Specifications
Max # Outputs1
Module Positions5
V1 Out Min (V)51
V1 Out Nom (V)60
V1 Out Max (V)72
Efficiency Rating (%)91
Operating Altitude (m)2000
Operating temperature range-5 to 45°C
SafetyIEC/EN 60950-1
IP RatingIP20
Control & MonitoringVIDI+ or VIDI+ I/O
OPUS C 12U are compact, 19" rack-mount DC power systems that offer a robust, free convection cooled, N+1 redundant backup power solution for telecommunications, process industry, transmission and distribution substations and other critical infrastructure applications.

The OPUS C 12U is a 19" self-contained rack-mount power system consisting of the MRC series rectifiers, VIDI+ controllers, mains and battery connections, and a wide selection of load distribution options. OPUS C systems are available in 24, 48, 60, 110, 125 and 220 VDC standard outputs and have a max output power of 8.0 kW.

The systems meet IEC 60950-1 safety standards and the following EMC standards: Emissions: IEC/EN 61000-6-4, Immunity: IEC/EN 61000-6-2, Harmonics: IEC/EN 61000-3-2, and Voltage Fluctuations & Flicker: IEC/EN 61000-3-3.

System options include a battery LVD, load LVD, extra battery connections, temperature sensor, wall-mount kit and IP21 kit.

All Efore DC power systems are configurable and scalable to meet individual application requirements. Contact us to show you how we can develop a custom system for you.

Ask our expert about OPUS C 12U DC Power Systems

When you submit this form, our specialist will be in touch with you by email or telephone. By submitting the form you accept our Privacy Policy.

CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.