Model NumberPower Out Max (kW)Input Voltage (VAC)Output Voltage Range (VDC)Output Current Max (A)Cooling
OPUS HE 60-6.0 R7U F6.0100 - 25051 - 72100Natural ConvectionMore info
Product Specifications
Module Positions3
V1 Out Min (V)51
V1 Out Nom (V)60
V1 Out Max (V)72
Output Current Min (A)33.3
Efficiency Rating (%)97
Operating Altitude (m)3000
Operating temperature range-25 to +60 Deg C
SafetyRack: EN61439-1, EN61439-2
IP RatingIP20
Control & MonitoringVIDI+ Controller
OPUS HE 125-6.0 R7U F6.0100 - 250100 - 16050Natural ConvectionMore info
Product Specifications
Module Positions3
V1 Out Min (V)100
V1 Out Nom (V)125
V1 Out Max (V)160
Output Current Min (A)16.7
Efficiency Rating (%)97
Operating Altitude (m)3000
Operating temperature range-25 to +60 Deg C
SafetyRack: EN61439-1, EN61439-2
IP RatingIP20
Control & MonitoringVIDI+ Controller
OPUS HE 125-6.0 R7U F6.0100 - 250178 - 28027.8Natural ConvectionMore info
Product Specifications
Module Positions3
V1 Out Min (V)178
V1 Out Nom (V)220
V1 Out Max (V)280
Output Current Min (A)9.3
Efficiency Rating (%)97
Operating Altitude (m)3000
Operating temperature range-25 to +60 Deg C
SafetyRack: EN61439-1, EN61439-2
IP RatingIP20
Control & MonitoringVIDI+ Controller
OPUS HE 110-6.0 R7U F6.0100 - 25090 - 15055.5Natural ConvectionMore info
Product Specifications
Module Positions3
V1 Out Min (V)90
V1 Out Nom (V)110
V1 Out Max (V)150
Output Current Min (A)18.5
Efficiency Rating (%)97
Operating Altitude (m)3000
Operating temperature range-25 to +60 Deg C
SafetyRack: EN61439-1, EN61439-2
IP RatingIP20
Control & MonitoringVIDI+ Controller
OPUS HE 24-4.5 R7U F4.5100 - 25021 - 33187.5Natural ConvectionMore info
Product Specifications
Module Positions3
V1 Out Min (V)21
V1 Out Nom (V)24
V1 Out Max (V)33
Output Current Min (A)62.5
Efficiency Rating (%)97
Operating Altitude (m)3000
Operating temperature range-25 to +60 Deg C
SafetyRack: EN61439-1, EN61439-2
IP RatingIP20
Control & MonitoringVIDI+ Controller
OPUS HE 48-6.0 R7U F6.0100 - 25042 - 59125Natural ConvectionMore info
Product Specifications
Module Positions3
V1 Out Min (V)42
V1 Out Nom (V)48
V1 Out Max (V)59
Output Current Min (A)41.7
Efficiency Rating (%)97
Operating Altitude (m)3000
Operating temperature range-25 to +60 Deg C
SafetyRack: EN61439-1, EN61439-2
IP RatingIP20
Control & MonitoringVIDI+ Controller
OPUS HE R7U SLAVE 5 x MHEMore info
Product Specifications
Module Positions5
The new OPUS HE 7U rack power system provides free air convection cooling, N+1 redundancy and is the ideal backup power solution for critical infrastructure applications such as transmission and distribution substations, process industries, railway signaling and substations, and telecommunications.

This new high efficiency rack power system consists of Efore's MHE rectifiers, VIDI+ controllers, connections for mains and 1 full current battery string, and bulk screw terminal for external load distribution. Available as a 19" 7U rack-mountable package, the system delivers a maximum 6 kW output power at 48, 60, 110, 125 and 220 VDC, and 4.5 kW at 24 VDC outputs. The base system supports up to three (3) MHE series high efficiency rectifiers, but may be expanded by using the 7U Slave rack in a master-slave configuration, increasing the power capability to 16 kW.

Optional accessories include a wall-mounting kit, IP21 cover kit, temperature sensor and Battery LVD.

All Efore DC power systems are configurable and scalable to meet individual application requirements. Contact us to learn how we can create a custom system for you. 

 

Ask our expert about OPUS HE 7U DC Power Systems

When you submit this form, our specialist will be in touch with you by email or telephone. By submitting the form you accept our Privacy Policy.

CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.